{"product_id":"omnixol-fx100-konzentrat","title":"Omnixol FX100 Concentrate","description":"\u003cdiv class=\"omnixol-produkttext\"\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eOmnixol FX100 Concentrate\u003c\/strong\u003e is a powerful cleaning concentrate\n    designed for treating surfaces and building materials contaminated with\n    heating oil, diesel, mineral oils, grease or comparable hydrocarbons.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    FX100 is particularly suitable for deep cleaning oil and heating oil damage\n    in basements, tank rooms and on absorbent mineral substrates such as\n    masonry, plaster, concrete and screed.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eHow Omnixol FX100 Works\u003c\/h2\u003e\n\n  \u003cp\u003e\n    FX100 is diluted with water before use. During treatment, oil-containing\n    contaminants are dispersed and emulsified. This helps mobilize hydrocarbons\n    from the pores and capillaries of the substrate and transport them toward\n    the surface.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    During this process,\n    \u003cstrong\u003emilky-white, damp or oily residues may appear on the surface\u003c\/strong\u003e.\n    This effect results from the mobilization of contaminants previously bound\n    within the substrate.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003e\n      FX100 contains no petroleum-based ingredients. The formulation consists\n      exclusively of compounds of plant origin.\n    \u003c\/strong\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003ca href=\"\/en\/pages\/wie-wirkt-omnixol-fx100\"\u003e\n      \u003cstrong\u003eHow does FX100 work within the substrate? Detailed explanation →\u003c\/strong\u003e\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\n  \u003cp\u003eOmnixol FX100 is particularly suitable for:\u003c\/p\u003e\n\n  \u003cul\u003e\n    \u003cli\u003eheating oil and oil damage in basements and tank rooms\u003c\/li\u003e\n    \u003cli\u003eoil-contaminated masonry and plaster\u003c\/li\u003e\n    \u003cli\u003econcrete and screed\u003c\/li\u003e\n    \u003cli\u003emineral floors and industrial flooring\u003c\/li\u003e\n    \u003cli\u003eoil- and grease-containing contamination on absorbent mineral surfaces\u003c\/li\u003e\n    \u003cli\u003eolder oil contamination in porous building materials\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\n    Even when no current oil leakage is visible, hydrocarbons may have penetrated\n    plaster, masonry, concrete or screed over many years and can continue to\n    cause odors.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eMixing Ratio\u003c\/h2\u003e\n\n  \u003cp\u003e\n    For heavy or deep-seated contamination, we recommend diluting FX100 at\n    approximately \u003cstrong\u003e1 : 10 with water\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    For normal to lighter contamination, FX100 can be diluted up to approximately\n    \u003cstrong\u003e1 : 20 with water\u003c\/strong\u003e. Warm water is recommended where possible.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003ePreparing the Substrate\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Before treatment, the substrate should be as dry as possible and free from\n    dust and loose contamination.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    For older heating oil contamination, we recommend bringing the affected area\n    to a temperature of at least approximately \u003cstrong\u003e20\u0026nbsp;°C\u003c\/strong\u003e before\n    application. Relative humidity should ideally remain below\n    \u003cstrong\u003e50\u0026nbsp;%\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Heating may temporarily intensify the heating oil odor because volatile\n    components can be released more strongly from contaminated building materials.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Water-repellent, oil-resistant or sealing coatings must be removed from the\n    contaminated area if they prevent the FX100 working solution from penetrating\n    into the underlying building material.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eHow to Apply FX100 Correctly\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The prepared FX100 working solution should be applied generously to the\n    contaminated substrate and worked into the surface.\n  \u003c\/p\u003e\n\n  \u003cp\u003eDepending on the surface, suitable tools include:\u003c\/p\u003e\n\n  \u003cul\u003e\n    \u003cli\u003escrubbing brush\u003c\/li\u003e\n    \u003cli\u003emasonry brush\u003c\/li\u003e\n    \u003cli\u003epressure sprayer\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\n    Absorbent surfaces must be treated with a sufficient amount of working solution.\n    Lightly wetting the surface is not sufficient for deep-seated contamination.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eContact Time\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The recommended \u003cstrong\u003econtact time is approximately 24 hours\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    During this period, mobilized contaminants may reach the surface together\n    with the cleaning solution and become visible as milky-white, damp or oily\n    residues.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eRemove Residues and Rinse with Clean Water\u003c\/h2\u003e\n\n  \u003cp\u003e\n    After the contact time, residues that have emerged or remain on the surface\n    should first be removed completely.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    The treated surface should then be\n    \u003cstrong\u003ethoroughly rinsed with clean water\u003c\/strong\u003e. The rinse water should\n    subsequently be completely removed using a wet vacuum or suitable absorbent\n    material.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    This removes remaining cleaning solution as well as mobilized oil and dirt\n    residues from the surface.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eCoverage\u003c\/h2\u003e\n\n  \u003cp\u003e\n    As a general guideline,\n    \u003cstrong\u003e1 liter of FX100 Concentrate is sufficient for approximately\n    10\u0026nbsp;m² of surface for a single treatment\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Actual consumption depends in particular on the absorbency of the substrate\n    as well as the severity and depth of the contamination.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    One thorough treatment is often sufficient. In cases of particularly heavy\n    or deep-seated contamination, a second application may be necessary after\n    the substrate has completely dried and the result has been assessed.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eDeep Contamination in Masonry\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Heating oil can penetrate deeply into plaster and masonry. It is therefore\n    essential that the FX100 working solution reaches the actual contaminated area.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    In cases of severe contamination, it may be advisable to remove contaminated\n    plaster before treatment. This provides direct access to the underlying masonry.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    For deep-seated contamination, targeted drill holes may additionally be used\n    to introduce the working solution deeper into solid mineral building components.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Before drilling, it must be ensured that cables, pipes, reinforcement,\n    waterproofing or other relevant building components cannot be damaged.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eAfter Treatment\u003c\/h2\u003e\n\n  \u003cp\u003e\n    After cleaning and rinsing, the treated substrate must\n    \u003cstrong\u003edry completely\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Further remediation steps such as replastering, coating or sealing should\n    only be carried out once the surface is dry and the original odor contamination\n    has been eliminated.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    This helps prevent remaining moisture or odor-causing substances from becoming\n    trapped within the building material.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eWhat to Do if Odor Remains\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Once the actual oil contamination has been treated and the substrate has\n    completely dried,\n    \u003ca href=\"\/en\/products\/omnixol-geruchsneutralisator-bx\"\u003e\n      \u003cstrong\u003eOmnixol BX Odor Neutralizer\u003c\/strong\u003e\n    \u003c\/a\u003e\n    can be used if residual odors remain.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    For heating oil and mineral oil damage, cleaning followed by odor\n    neutralization forms the Omnixol Two-Step System.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003ca href=\"\/en\/pages\/omnixol-zwei-stufen-prinzip\"\u003e\n      \u003cstrong\u003eLearn more about the Omnixol Two-Step System →\u003c\/strong\u003e\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eSafety Information\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Before use, please observe the information provided in the product information\n    sheet and the current safety data sheet.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    When working in heavily oil-contaminated or heated rooms, adequate ventilation\n    must be ensured. Suitable personal protective equipment should be used\n    according to the specific working conditions.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    When handling heating oil and mineral oil damage, potential ignition sources\n    in the working area must be avoided.\n  \u003c\/p\u003e\n\n\n  \u003ch2\u003eApplication \u0026amp; Further Information\u003c\/h2\u003e\n\n  \u003cul\u003e\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/gebrauchsanweisung-omnixol-fx100\"\u003e\n        \u003cstrong\u003eDetailed FX100 Instructions for Use\u003c\/strong\u003e\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/wie-wirkt-omnixol-fx100\"\u003e\n        How Does Omnixol FX100 Work?\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/heizoelgeruch-aus-wand-und-boden-entfernen\"\u003e\n        Remove Heating Oil Odor from Walls and Floors\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/oeltankraum-richtig-sanieren\"\u003e\n        How to Remediate an Oil Tank Room\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/oelflecken-aus-beton-entfernen\"\u003e\n        Remove Oil Stains from Concrete\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/heizoelprobleme-nach-hochwasser\"\u003e\n        Heating Oil Contamination After Flooding\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003ca href=\"\/en\/pages\/faq\"\u003e\n        Frequently Asked Questions About Omnixol FX100\n      \u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Omnixol","offers":[{"title":"1 Liter","offer_id":55409260298567,"sku":"SR\/FXK1","price":69.0,"currency_code":"EUR","in_stock":true},{"title":"5 Liters","offer_id":55409260331335,"sku":"SR\/FXK5","price":299.0,"currency_code":"EUR","in_stock":true},{"title":"10 Liters","offer_id":55409260364103,"sku":"SR\/FXK10","price":569.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1017\/0489\/2743\/files\/OMNIXOL_FX100_1L.jpg?v=1791983288","url":"https:\/\/www.omnixol.de\/en\/products\/omnixol-fx100-konzentrat","provider":"Omnixol","version":"1.0","type":"link"}